TABLE OF CONTENTS
1. Features ............................................................................................5
2. Technical Information .....................................................................5
3. Safety Precautions ..........................................................................6
4. Installation .......................................................................................6
5. Operating Instructions ...................................................................7
6. Fault codes.......................................................................................9
7 . Service and Troubleshooting ........................................................9
1. Features
1.1. Microprocessor-controlled
1.2. Able to auto identify battery's capacity
1.3. Able to adapt to State of Charge (SoC)
1.4. Compatible with battery voltages of:
1ph
12V
24V
36/48V
1.5. Unique profile for charging Thin Plate Pure Lead (TPPL)
1.6. Unique profiles for NexSys
®
battery charge applications: NXBLOC;
NXSTND.
1.7.
Fully programmable to unique fleet requirements.
1.8. Battery chemistry agnostic - TPPL, Flooded and Gel Lead Acid.
2. Technical Information
2.1. Name plate labels
TC3 IMP
3ph
24/36/48V
72/80V
96V
120V
BATTERY CHARGER
INSTRUCTIONS FOR USE
2.1.1. Name plate label definitions
Item
Serial Number
Input voltage frequency. Under no conditions operate
Hertz
the charger at a different frequency or from a generator
TCX. When "1" indicates a Single Phase Charger
Phase
and "3" indicates a Three Phase Charger.
AC Volts
Nominal voltage for which this charger is rated to operate.
DC Volts
Nominal DC output voltage of the charger
Actual number of power modules installed
Modules
DC current that this charger will deliver to a discharged
DC Amps
battery with the number of power modules installed
and based on the Nominal Voltage
2.1.2. Output power letter codes
Output Power
(kW)
1.0
2.0
3.0
3.5
7.0
10.5
14.0
17.5
21.0
24.5
28.0
2.1.3. Cabinet size (number of modules available) and DC cable size
Module
Standard
Phases
Positions
Cable Gauge
1ph
Max 1
6 mm
1ph
Max 3
25 mm
3ph
Max 2
35 mm
3ph
Max 4
70 mm
3ph
Max 6
95 mm
70 mm
3ph
Max 8
or 1 x 95
mm
5
ENGLISH
Description
Provides date code.
with unstable frequency.
in the charger cabinet.
Number
Module Power
Modules
(kW)
1
1.0
2
1.0
3
1.0
1
3.5
2
3.5
3
3.5
4
3.5
5
3.5
6
3.5
7
3.5
8
3.5
Comments
stand alone cabinet
2
2
Three slot, 3 kW cabinet
2
Two slot, 7 kW cabinet
Four slot, 3.5 to 14 kW cabinet
2
Six slot, max 21 kW cabinet
2
Eight slot, max 28 kW cabinet.
2
Dual cable for 24/36/48Vdc single
cable for 72/80Vdc
2