Application
Operation is possible in conjunction with:
- Pressurized storage heaters
- Thermally controlled instantaneous heaters
- Hydraulically controlled instantaneous heaters
Operation with low-pressure storage heaters
(displacement water heaters) is not possible.
Technical data
• Max. flow
• Flow pressure
- min.
- recommended
- greater than 72.5 psi, fit with pressure reducing
valves
• Max. operating pressure
• Test pressure
• Temperature
- max. (hot water inlet)
• Water connection
Notes
- An access panel must be provided for access to
hose connections.
- Major pressure differences between cold and hot
water supply should be avoided.
Installation
Layout dimensions to establish proper clearances, see
dimensional drawing on page 1.
Flush pipes thoroughly!
Side valves
• Valve with a groove on the top edge of the
cartridge (A) and in addition marked with blue tape
should be mounted on the right (cold water) side,
see fig. [1].
• Valve without a groove on the top edge of the
cartridge (A) and in addition marked with red tape
should be mounted on the left (hot water) side.
1. Screw the mounting set (B) to the bottom of the
thread of the side valve (C), see fig. [1].
Make sure that the rubber washer (B1) is on the top
of the fiber washer (B2).
2. Insert the side valve (C) through the basin hole from
below.
3. Place the escutcheon O-ring (D1) on the basin and
screw down the escutcheon (D) until it stops.
4. Screw the cap (E) down to the escutcheon (D).
5. Tighten the mounting set (B) from below to secure
the valve.
approx. 50 L/min or 13.2 gpm
14.5 - 72.5 psi
cold - Right hand
hot - Left hand
English
Mount handle (18 731) or lever (18 732), sold
separately, see fig. [1].
Cross handle (F):
- Secure the handle (F) to the stem of the
cartridge (A).
Lever handle (G):
1. Slide ring (G2) on lever (G).
2. Push on lever (G) and tighten with set screw (G1).
3. Screw the ring (G2) into the cap (E) until tight.
Hand tighten only!
It is recommended that the lever (G) be installed so
they point away from the spout when in the off position.
7.25 psi
Spout, see fig. [2].
1. Place the O-ring (I1) and the escutcheon (H1) on the
basin.
2. Insert the spout (H) through the escutcheon (H1)
145 psi
and basin.
232 psi
3. Secure the spout with the mounting set (I).
4. Install the connector (J) to the spout.
176 °F
Connect faucet, see fig. [3].
Install elbows (K) onto the diverter (L).
Connect the side valves to the water supply. Insure the
supplied washers are used for all connections.
The cold water supply should be connected on the
right side valve (marked blue) and the hot water supply
to the left valve (marked red).
Open cold and hot water supply and check
connections for leakage.
Maintenance
Inspect and clean all parts, replace as necessary and
grease with special grease.
Shut off cold and hot water supply.
I. Ceramic cartridge, see page 2.
1. Remove handle (18 731) or lever 18 732) and cap.
2. Unscrew the ceramic cartridge (45 882, 45 883)
using a 17mm wrench.
3. Change complete ceramic cartridge or O-ring.
Observe the different replacement part numbers of
the cartridges.
II. Flow straightener, see page 2.
Unscrew and clean flow straightener (13 934).
Assemble in reverse order.
Replacement parts, see page 2 ( * = special
accessories).
Care