ENGINE MAINTENANCE
WARNING
WHEN
ADJUSTING
OR MAKING
REPAIRS
TO YOUR
GENERATOR
Disconnect
the spark plug wire from the spark
plug and
place the wire where
it cannot
contact
spark plug.
WHEN TESTBNGFOR ENGINE SPARK
Use
approved
spark
plug
tester.
DO NOT check for
spark with spark
plug
removed.
Checking
OH Leve_
Oil level should be checked prior to each use or at least
every 5 hours of operation. Keep oil level maintained.
Changing
Engine
OH
Change the oil after the first 5 hours of operation.
Change oil every 50 hours or once each year,
whichever comes first, thereafter. If you are using your
generator under extremely dirty or dusty conditions, or
in extremely hot weather, change the oil more often.
Change the oil while the engine is still warm from
running,
as follows:
1.
Place generator on a level surface.
2.
Disconnect spark plug wire and keep it away from
spark plug. Disconnect battery at negative terminal.
3.
Clean area around oil drain plug. The oil drain
plug is located at base of engine, opposite
carburetor.
4.
Remove oil drain plug and oil fill cap and drain oil
completely into a suitable container.
5.
Install oil drain plug and tighten securely.
6.
Fill oil sump with recommended oil to the point of
overflowing. See page 7 for oil recommendations.
7.
Install oil cap. Tighten cap securely.
8.
Wipe up any spilled oil
CmeantRep[ace
Spark
Plug
Change the spark plug every 100 hours of operation
or once each year, whichever comes first. This will
help your engine to start easier and run better.
1.
Clean area around spark plug.
2.
Remove and inspect spark plug.
3.
Check electrode gap with wire feeler gauge and set
spark plug gap to 0.030 inch (0.76mm) if necessary.
/.
4.
Replace spark plug if electrodes are pitted, burned
or porcelain is cracked. Use a recommended
replacement plug.
NOTE: You can purchase a new spark plug by calling
1-800-366-PART.
Service
Air Cleaner
Your engine will not run properly and may be
damaged if you run it using a dirty air cleaner. Clean
or replace the air cleaner paper filter once every
25 hours of operation or once a year, whichever
comes first. Clean or replace more often if operating
under dusty or dirty conditions.
,Service.Air Filter
1.
Loosen
screws
and remove air cleaner cover.
Remove paper filter.
Cartridge
Cover
Base
2.
Install clean (or new) air cleaner assembly inside
cover. Dispose of old filter properly.
3.
Assemble air cleaner cover onto base and tighten
screws.
NOTE: You can purchase new air cleaner elements by
calling 1-800-366-PART.
Carburetor
if you think your carburetor needs adjusting, see your
nearest Sears service center. Engine performance
may be affected at altitudes above 3000-5000 feet.
For operation at higher elevations, contact your
nearest Sears service center.
CJean Spark
Arrester
Screen
The engine exhaust muffler has a spark attester
screen. Inspect and clean the screen every 100 hours
of operation or once each year, whichever comes first.
NOTE: You can purchase a new spark attester screen
by calling 1-800-366-PART.
If you use your generator on any forest-covered, brush-
covered, or grass-covered unimproved land, it must
have a spark attester. The spark arrester must be
maintained in good condition by the owner/operator.
14