UNINSTALLATION & CONVERSION BACK TO ORIGINAL
UNINSTALLATION OF LIQUID PROPANE CONVERSION SAFETY PILOT KIT (See Figure 12)
1. Insure the gas is shut off at the main shut-off valve
2. Remove the pilot assembly by unscrewing the (2) screws holding the pilot to the pilot bracket.
a. Unscrew the pilot tube from the Safety Pilot Kit (SPK) valve.
b. Unscrew the thermocouple line from the SPK valve.
c. Remove the piezo wire from the piezo starter
3. Remove the SPK assembly by rotating the entire assembly counter clockwise
4. Remove the nozzle from the burner tube by turning counter clockwise.
CONVERTING BACK TO NG WITHOUT SAFETY PILOT KIT, FROM LP (See Figure 13)
1a. Thread the keyed shut-off valve to the fireplace gas
supply pipe. Use thread sealant.
1b. If a keyed shut-off valve is already installed, thread 1/2" female connector to the fireplace gas supply pipe.
Use thread sealant.
2. Thread adapter fitting into keyed shut-off valve (or 1/2" Female Connector).
3. Install NG 3/8" orifice fitting onto the burner inlet fitting using thread sealant on male threads of burner
inlet fitting.
NOTE: This fitting was supplied with the original Vented Gas Log model. If this is missing refer to the parts
list in the Vented Gas Log Owners Manual, and order a new part. DO NOT operate the appliance without the
correct orifice fitting (Item #80-06-034).
4. Install the gas flex tube to the adapter fitting. Carefully shape tube to attach to orifice fitting.
SPK Assembly
Main Gas Connection
Turn Counterclockwise
Step 3:
Fig. 12
Step 2b:
Step 4:
Thermocouple Wire
Nozzel
Step 2a:
Pilot Tube
Step 2:
Pilot Assembly Screws
Step 2c:
Piezo Wire
Step 1a: Keyed shut-off valve
Step 1b: 1/2" Female Connector
20
Fig. 13
Step 3: NG 3/8" Orifice Fitting
Step 4: Flex Tube
Step 2: Adapter fitting
or