REMOTE CONTROL OPERATION
WIRING INSTRUCTIONS
Make sure the remote receiver switch is in the OFF position. For
best results it is recommended that 18 gauge stranded wires
should be used to make connections and no longer than 20-feet.
This remote receiver is to be connected to a manual valve with a
latching ON/OFF solenoid.
Connect two 18 gauge stranded or solid wires from the remote
receiver terminals to the latching solenoid. (See figure to the right)
IMPORTANT NOTE: Operation of this control is dependent on
which wire is attached to which terminal. If operation of control
does not correspond to operating buttons on transmitter, reverse
wire installation at the receiver or at the control. NOTE: Up to 6.3
VDC of power is provided at the receiver terminal.
GENERAL INFORMATION
COMMUNICATION – SAFETY – TRANSMITTER – (C/S – TX)
This remote control has a COMMUNICATION –SAFETY function built into its software. It provides an extra
margin of safety when the TRANSMITTER is out of the normal 20-foot operating range of the receiver.
The COMMUNICATION – SAFETY feature operates in the following manner, in all OPERATING MODES –
ON/ ON THERMO.
At all times and in all OPERATING MODES, the transmitter sends an RF signal every fifteen (15) minutes, to
the receiver, indicating that the transmitter is within the normal operating range of 20-feet. Should the receiver
NOT receive a transmitter signal every 15 minutes, the IC software, in the RECEIVER, will begin a 2-HOUR
(120-minute) countdown timing function. If during this 2-hour period, the receiver does not receive a signal
from the transmitter, the receiver will shut down the appliance being controlled by the receiver. The RECEIVER
will then emit a series of rapid "beeps" for a period of 10 seconds. Then after 10 seconds of rapid beeping,
the RECEIVER will continue to emit a single "beep" every 4 seconds until a transmitter ON or MODE Button
is pressed to reset the receiver. The intermittent 4-second beeping will go on for as long as the receiver's
batteries last which could be in excess of one year.
To "reset" the RECEIVER and operate the appliance, you must press the ON button on the transmitter. By
turning the system to ON, the COMMUNICATION -SAFETY operation is overridden and the system will return
to normal operation. The COMMUNICATION – SAFETY feature will reactivate should the transmitter be taken
out of the normal operating range or should the transmitter's batteries fail or be removed.
Reveiver
Slide
Button
Reveiver
Slide
Button
26
Remote Receiver
Wire terminals
LEARN
REMOTE
LEARN
REMOTE
ON
Remote Receiver
WirePulse Connection
Concentric Valve
Black Wire
Red Wire
PULSE MODE
Terminals