INSTALLATION
This safety pilot system must be installed by a qualified
profession service technician.
Note: Installation is easier when done outside of the
fireplace.
Save the orifices removed from the appliance for future
use.
WARNING: It is mandatory you use the correct orifice size and gas type for your installation.
Failure to do so will result in either a weak flame or an excessively large flame which could
cause overheating and result in property damage or injury.
Conversion Safety Pilot Kit Assembly Instructions
1. Determine which side of the burner assembly the
control will be on – Left or Right and attach ON/OFF
Label to Valve Bracket.
-This assembly illustration shows the control on the
right side.
2. Remove Control Valve Assembly from carton and all
the other components.
3a. Remove the original fittings from the Burner Tube.
3b. Install either the LP or NG Air Shutter depending on
your fuel source.
Save the original fittings you removed in case you
return the unit to the standard design!
WARNING: Failure to position the
parts in accordance with these
diagrams or failure to use only parts
specifically approved with this appli-
ance may result in property damage
or personal injury.
2.
SPK200L
Control Valve Assembly
3.
LP Air Shutter
9
SPK300L
Control Valve Assembly
Burner Pan Assy.
Burner Tube
NG Air Shutter