ETV STR61-50-B10
Installation
Installation requirements
Installation
Connecting tool
The tool should, via its correct Power Focus drive unit, be connected to the mains, 230V/50Hz alterna-
tively 115V/ 60Hz, single phase. See instructions for your Power Focus drive unit.
Tool display
The tool display is turned on from the controller.
On Power Focus 4000:
■
Push the Prog button
■
Use the navigation buttons to follow the path > Tool > Configuration > Accessory bus > ST bus >
Mode
Socket release function
It is recommended to use the socket release function on all the ETP ST101 tools. When the function is en-
abled, the socket rotates backwards 3
reaction bar and to make it easier to remove the tool.
The socket release function is turned on from the controller.
On Power Focus 4000:
■
Push the Prog button
■
Use the navigation buttons to follow the path > Pset > Programming+ > Options > Socket release >
Mode On
Installation instructions
Fitting of the tool cable
■
Security check that the cable type is correct
■
Align the cable connector using the two asymmetrically positioned heads on the connector to fit in the
slots in the tool handle.
■
Tighten the lock nut.
■
Security check that the connection is correct by pulling, pushing and turning the cable connector
(there should be no movement).
The tool has a built in electronic memory chip that will transmit the torque transducer calibration value
and angle pulses to the POWER FOCUS/drive unit. Any changes made of these values in the
POWER FOCUS while the tool is connected will be stored in the tool memory.
Preventing ESD problems
The components inside the tool and controller are sensitive to electrostatic discharge. To avoid future mal-
function, make sure that service and maintenance is carried out in an ESD approved work environment.
The figure below shows an example of an appropriate service work station.
EN
o
after a completed tightening. The aim is to reduce tension on the
© Atlas Copco Industrial Technique AB - 9836 9815 00
Installation
5