Troubleshooting
Fault
Pipe deburrer switches off.
Spare parts
Available Geberit spare parts
Article no.
90364
90365
90366
691.142.00.1
Maintenance
Authorised repair shops
The addresses of authorised repair shops can be requested from the Geberit sales
companies.
Maintenance regulations
If the Geberit Mapress electric pipe
deburrer RE 1 is not maintained or not
maintained properly, serious accidents can
be caused. It is essential to observe the
maintenance intervals and maintenance
work outlined below.
9376181515 © 02-2022
964.873.00.0(02)
Cause
Carbon brushes are worn.
Designation
Deburrer head for Geberit Mapress electric pipe
deburrer RE 1
Milling cutter for Geberit Mapress electric pipe
deburrer RE 1
Geberit protective goggles
Case for Geberit Mapress electric pipe deburrer RE 1
Interval
Regularly
(before use,
at the start of
the working
day)
Action
Have an electrically skilled
person or an authorised
repair shop replace the
carbon brushes.
Maintenance work
▶ Clean the ventilation
slots by blowing them
out.
▶ If the cutting
performance of the
milling cutter drops,
clean it with a wire
brush.
▶ Replace the damaged
milling cutter and take it
out of service.
EN