Checking before use
Operation ranges
The table below indicates the temperature and humidity ranges the air
conditioner can be operated within. Refer to the table for efficient use.
Mode
Indoor temperature
Cooling
Heating
Dry
f If the air conditioner operates in cooling mode for long period of time in high humidity area, dew may be formed .
f If the outdoor temperature goes down to -5 °C, heating capacity may decrease as much as 60 %~70 % of specified
capacity according to the using conditions .
Maintaining your air conditioner
Internal protections via the unit control system
f This internal protection operates if an internal fault occurs in the air conditioner .
Type
Against cold air
Defrost cycle
Protect compressor
• I f the heat pump is operating in Heat mode, defrost cycle is actuated to help remove frost from an outdoor
unit that may have deposited at low temperatures.
The internal fan is switched off automatically and restarted only after the defrost cycle is completed.
Checking the name of the parts
Your air conditioner may slightly look different from illustration shown below depending on your model.
Main parts
Midea ODM Latin America IB&IM_HP_EN.indd 10
Outdoor temperature
17
˚C~32
˚C
17 ˚C~43 ˚C
0 ˚C~30 ˚C
-7 ˚C~24 ˚C
10 ˚C~32 ˚C
17 ˚C~43 ˚C
The internal fan will be off to prevent cold air when the heat pump is heating.
The internal fan will be off to defrost ice when the heat pump is heating.
Vertical air flow blade will be closed during defrost cycle and it will open again during
heating operation after defrost cycle.
The air conditioner does not start operating immediately to help protect the compressor
of the outdoor unit after it has been started.
Air intake
Air flow blade
(up and down)
English-10
Indoor humidity
Relative humidity 80% or less
-
-
Description
Air flow blade
(left and right)
2014/6/11 11:42:33