Connecting the assembly cable
2 . Open the cover panel.
3 . Remove the screw securing the connector cover.
4 . Pass the assembly cable through the rear of the indoor unit and connect the assembly cable to terminals.
(Refer to the picture below)
• E ach wire is labeled with the corresponding terminal number.
5 . Pass the other end of the cable through the 65 mm hole in the wall.
6 . Close the connector cover by tightening the screw carefully.
7 . Close the cover panel.
8 . Remove the terminal board cover on the side of the outdoor unit.
9. Connect the cables to the terminals as seen in the picture.
• E ach wire is labeled with the corresponding terminal number.
Indoor unit
Outdoor unit
• Also circular terminal must be matched with screw size in terminal block.
• After connecting the cables, make sure terminal numbers on the indoor/outdoor unit matches.
• P lease ensure that Power & Communication cables are separated, they must not be in the same cable.
10. Connect the grounding conductor to the grounding terminals.
11. Close the terminal board cover by tightening the screw carefully.
• I n Russia and Europe, consult with the supply authority to determine the supply system impedance before
installation.
• C onnect the wires firmly so that wires can not be pulled out easily.
(If they are loose, it could cause burn-out of the wires.)
• C onnect the wires according to color codes, referring to the wiring diagram.
• T he power cable and the interconnection cable should be selected according to the specification in page 35.
Midea ODM Latin America IB&IM_HP_EN.indd 36
Terminal block
Wire cover
Terminal block of
Screw
indoor unit
Screw
Cable clamp
Terminal block
Cover
Terminal block of
Screw(1~2,model
outdoor unit
dependent)
Cable clamp
English-36
No need to be
connected.
09/12/18
1 2(N) 3 4
L
Cable clamp
To outdoor unit
09/12/18
1
2(N)
3
4
Cable clamp
To indoor unit
24
1 2(N)
3
4
5
To outdoor unit
24
1
2(N)
3
4
5
To indoor unit