Wash all the components with water and neutral soap.
Use a clean cloth or a soft brush to remove residues.
Wash, sanitize, rinse and dry all the components.
Assemble back all the components following the inverse
path, and make sure all the components are correctly in
place.
Use Your QR Code Reader to access more
information regarding the cares needed
when handling Stainless Steel.
6. MAINTENANCE
Maintenance must be considered a set of procedures
with the purpose to keep the equipment best operating
conditions, therefore increasing the equipment life and
safety.
Cleaning – check item 5 Cleaning
Wiring - Check all wires regarding deteriorate conditions as
well as all electric contacts (terminals) regarding tightening
and corrosion .
Contacts – ON/OFF switch, emergency button, reset button,
electronic circuits etc., check the equipment in order to
assure that all components are correctly working and the
equipment operation is normal.
Installation – make sure the installation followed item 2.1
instructions
Working Life - 50.000 cycles as per normative.
1 – Each month check :
- Check the electrical installation
- Measure the voltage at the socket
- Measure the working current and match it with the
nominal current
- Check the tightening of all electric terminals to avoid bad
contacts
- Check electric motor shaft clearance
- Check the wiring for overeating, insulation failures and
mechanical damages .
2 – Lubrificate the bearings once each 2 months
Recommended Grease: Grease MP2 GBR (lithium based).
3 – Each three month checks
- Check electrical components such as ON/OFF switch,
emergency button, reset button, electronic electric circuits,
overeating, insulation failings, or mechanical damages
- Check bearings clearances
- Check retainers, O'rings, V'rings and other seals.
Use Your QR Code Reader to access
more information regarding safety and
maintenance.
6