EN
DESCRIPTION
Compressed air powered reciprocating piston pump. This high flow capacity pump is compatible with mineral and synthetic oils and suitable for
large installations with long length piping supplying several fluid outlets simultaneously.
This pump can be mounted on the wall, with wall mounting bracket (Part. No. 360140, 360139), or directly on a drum or tank, using a suction
tube of a suitable length. All pumps bundle a bung adapter, except references xxxx8x.
INSTALLATION
These pumps can be installed directly on a drum or tank. However, we
recommend installation with a wall-mounting bracket (360140/360139).
They can be installed in three different ways:
a. Wall mounting with bung adapter. Insert the pump through the
wall bracket (360140) and attach it with the bung adapter
(360001) (Fig. 1).
b. Wall mounting with screws. Insert the pump through the wall
bracket (360140) and fix it with 4xM8 screws (Fig. 2).
C. Adjustable drum or tank mounting, using bung adapter (360001).
Screw the proper suction tube (see Fig. 3) to the foot valve of the
pump. Screw the nut of the bung adapter to the 2" opening of the
cover. Insert the suction tube through the nut and secure it with the
star nut at the desired height.
In those cases in which it is required to comply with ATEX conditions,
be sure to ground the pump with the cable equipped with
a clamp (534907).
534907
OPERATION
This pump is self-priming. To prime it the first time, you must connect the air supply to the pump and slowly increase the air pressure from 0 to
the desired pressure using a pressure regulator. The pump starts to pump when an outlet valve is opened, for example an oil control gun.
4
853 822 R. 03/23
SAMOA Industrial, S.A. · Pol. Ind. Porceyo, I-14 · Camino del Fontán, 831 · 33392 - Gijón - Spain · Tel.: +34 985 381 488 · www.samoaindustrial.com
360140
Fig. 2
534907
Fig. 1
SUCTION TUBE
PUMP
DRUM
535530 / 535580
753242
535531 / 535581
753244
535510
Included
535511
Included
360001
360139
Fig. 3
TANK
368112
539041
-
-