Appendix 1
Code:
d
Meaning:
Relay not open
(stopped).
Telephone fault finding action:
Send engineer.
On site fault finding action:
Replace main board.
F
Code:
F
Meaning:
Brake semi-conductor failed.
Telephone fault finding action:
Send engineer.
On site fault finding action:
Replace main board.
H
Code:
H
Meaning:
Relay not open
(pre delay).
Telephone fault finding action:
Send engineer.
On site fault finding action:
Replace main board.
L
Code:
L
Meaning:
Current limit exceeded.
Telephone fault finding action:
Check client understands loading limits.
Send engineer if persistent fault.
On site fault finding action:
Check motor and track for obstructions.
MINIVATOR SIMPLICITY + INSTALLATION MANUAL
28
Description:
The main power relay
is welded closed.
Description:
Description:
The main power relay
is closed early.
Description:
E
Code:
E
Meaning:
Relay not closed.
Telephone fault finding action:
Send engineer.
On site fault finding action:
Check battery voltage and replace if necessary,
otherwise replace main board.
Code:
g
Meaning:
Brake not connected.
Telephone fault finding action:
Send engineer.
On site fault finding action:
Check brake.
L
Code:
J
Meaning:
Hinge interlock switch error.
Telephone fault finding action:
Send engineer.
On site fault finding action:
Replace hinge interlock roller switch.
Code:
n
Meaning:
Half speed.
Telephone fault finding action:
Send engineer if permanently showing unless SlideTrack is installed.
On site fault finding action:
Check reed switches and dip switch settings.
Check battery voltage.
Description:
The main power relay did not close.
Description:
Description:
Description: