Code:
o
Meaning:
Default Eeprom.
Telephone fault finding action:
Send engineer.
On site fault finding action:
Replace main board.
Code:
r
Meaning:
No charge current.
Telephone fault finding action:
Check that power supply is switched on from mains supply.
If yes send engineer.
On site fault finding action:
Check power supply.
Code:
Y
Meaning:
Main board error.
Telephone fault finding action:
Send engineer.
On site fault finding action:
Replace main board.
8
Code:
N/A
Meaning:
Lift is in "sleep mode"
to conserve battery power.
Telephone fault finding action:
None.
On site fault finding action:
Press toggle or handset button to wake lift.
Description:
The Eeprom has been reset
to its default value (Flash Failure).
Description:
Activated.
Description:
The main control board
has a fault.
Description:
P
Code:
P
Meaning:
PS no reply.
Telephone fault finding action:
NOT YET ACTIVE.
On site fault finding action:
NOT YET ACTIVE.
u
Code:
U
Meaning:
No float indication V1.19
software and later only.
Telephone fault finding action:
Send engineer.
On site fault finding action:
Check power supply.
Code:
N/A
Meaning:
Over current.
Telephone fault finding action:
Send engineer with a service exchange power pack.
On site fault finding action:
Replace power pack.
NOTE: If the display is showing
anything but the diagnostic codes
listed it requires resetting.
Drive the lift off the charge contacts.
Turn the main switch on the unit off
for 10 seconds and then back on.
MINIVATOR SIMPLICITY + INSTALLATION MANUAL
Appendix 1
Description:
Powered swivel did not respond.
Description:
Faulty power supply.
Description:
29