1
Safety instructions
Junction Box Ex d
Before using the product, carefully read the instructions for use of the gas
detector used. This document does not replace the instructions for use.
2
Description
2.1
Product overview
X
1
2x
2x
12x
2
Assembly instructions
|
Junction Box Ex d
Y
2x
4
3
X
Remote cable harness set for Polytron
Y
Remote cable harness set preassembled in Junction Box Ex d
1
Screws for mounting the remote cable harness in Polytron
2
Screw bridges for mounting in the remote cable harness set Polytron
5000/8000 (for 3-core field wiring)
3
Screw bridges for mounting in the remote cable harness set Y (for 3-core
field wiring)
4
Ferrules for field wiring
1)
Not relevant for PointGard 3200 CAT
2.2
Intended use
The Junction Box Ex d is an explosion-proof sensor enclosure that makes it
possible to install the sensor separately from the transmitter. The housing
consists of robust stainless steel or aluminum and is suitable for indoor or
outdoor applications.
The Junction Box Ex d is suitable for wall, ceiling and duct mounting.
Duct mounting requires additional connection kits.
3
Installation
Prerequisite:
®
–
When using a Polytron,
first unscrew the sensor from the transmitter.
The Junction Box Ex d can be used to measure gases in the ambient air or
within pipes/ducts.
1. Mount the Junction Box Ex d with M6 (1/4") hexagon socket head cap
screws to one of the following options
Option
Mounting on a flat surface
|
Safety instructions
®
1)
5000/8000
®
5000/8000
®
1)
Drilling template: 4544299
®
For Polytron
87x0 IR additionally
6812617
en
1)
7