Installation
5.1
Select location
Requirement(s):
ü Technical data and mains data are the same.
1 "4 Technical data" [} 9]
ü Permissible ambient conditions are observed.
ü The product and the charging station are in suf-
ficient proximity to each other, depending on
the length of the charging cable used.
ü The following minimum clearances to other ob-
jects (e.g. walls) must be complied with:
n Distance to left and right: 300 mm
n Distance above: 300 mm
5.1.1 Permissible ambient conditions
DANGER
Risk of explosion and fire
If the product is operated in potentially explosive
areas (ex areas), explosive substances may be ig-
nited by sparking of product components. There is
a risk of explosion and fire.
u Do not use the product in potentially explosive
atmospheres (e.g. gas filling stations).
ATTENTION
Material damage due to unsuitable ambient con-
ditions
Unsuitable ambient conditions can damage the
product.
u Protect the product from a direct water jet.
u Avoid direct sunlight.
u Ensure adequate ventilation of the product. Ad-
here to minimum distances.
u Keep the product away from heat sources.
u Avoid large temperature fluctuations.
Permissible ambient conditions
Ambient temperature [°C]
Average temperature over 24
hours [°C]
Altitude [m above sea level]
Relative humidity (non-con-
densing) [%]
5.2
Preparatory work on site
5.2.1 Upstream electrical installation
The tasks described in this section may only
be carried out by a qualified electrician.
DANGER
Fire hazard due to overload
If the upstream electrical installation is flawed (e.g.
supply line), there is a fire hazard.
u Design the upstream electrical installation ac-
cording to the applicable regulatory standards
and the technical data and configuration of the
product.
1 "4 Technical data" [} 9]
When configuring the supply line (cross
section and cable type), give due consider-
ation to the following local conditions:
n Type of installation
n Line length
u Route the supply line and the control / data line,
if applicable, to the desired location.
Installation options
n On a wall
n On the pole from MENNEKES
Wall mounting:
The supply line must be positioned using the
drilling template provided or the figure "Drilling di-
mensions [mm]".
Min.
Max.
-30
+50
EN
+35
2,000
95
11