WARNING
This icemaker uses CFC-free refrigerant
(propane) and CFC-free foam insulation that
are non-ozone-depleting and environmentally
sustainable materials having very low global
warming potential.
The CFC-free refrigerant is flammable and
sealed in the refrigeration system. Although
the refrigerant does not leak out under normal
usage, take utmost care when handling this
icemaker so as not to cause any damages to
the system. In the case of accidental damage
to the refrigeration system causing refrigerant
leak, do not create a source of ignition in the
area. Do not operate electrical switches or
plugs in the area, do not use naked flame.
Immediately ventilate the area by opening doors
and/or windows, and call service engineer.
IMPORTANT
. This booklet is an integral and essential
part of the product and should be kept and
preserved by the user. Please read carefully
the guidelines and warnings contained herein
as they are intended to provide the user
with essential information for the continued
safe use and maintenance of the product. In
addition, it provides GUIDANCE ONLY to the
user on the correct services and site location
of the icemaker. Please preserve this booklet
for any further consultation that may be
necessary.
2. This is a commercial icemaker, and should
be destined only to be used for the purpose
for which it has been expressly designed.
Any other use should be considered improper
and therefore dangerous. The manufacturer
will not be held liable or responsible for any
damage caused by improper, incorrect and
unreasonable use.
I. INSTALLATION INSTRUCTIONS
WARNING
. The installation must be carried out
by qualified personnel, in accordance
with current regulations, according to the
manufacturer's instructions.
2. Keep ventilation openings, in the appliance
enclosure or in the built-in structure, clear of
obstruction.
3. Do not use mechanical devices or other
means to accelerate the defrosting process,
other than those recommended by the
manufacturer.
1. LOCATION
IMPORTANT
. This icemaker is not intended for outdoor
use. Normal operating ambient temperature
should be within 5°C to 40°C. Normal
operating water temperature should be within
5°C to 35°C. Operation of the icemaker, for
extended periods, outside of these normal
temperature ranges may affect production
capacity.
2. The icemaker should not be located next to
ovens, grills or other high heat producing
equipment.
3. The location should provide a firm and level
foundation for the equipment.
4. Allow 5 cm clearance at rear and sides
f o r p r o p e r a i r c i r c u l a t i o n a n d e a s e o f
maintenance and/or service should they be
required. Allow 60 cm clearance on top to
allow for removal of the Auger.
5. This appliance is not suitable for installation
in an area where a water jet could be used
and where dripping is not allowed.
6. Do not place anything on top of the icemaker
or in front of the Louver.
7. Avoid prolonged exposure of the appliance
to direct sunlight.
8. T h i s a p p l i a n c e c o n t a i n s f l a m m a b l e
refrigerant in its cooling unit; maintenance
and recharging must therefore only be
carried out by authorized technicians.
2. ELECTRICAL CONNECTIONS
WARNING
THIS APPLIANCE MUST BE EARTHED
This icemaker requires an earth that meets the
national and local electrical code requirements.
To prevent possible severe electrical shock to
individuals or extensive damage to equipment,
install a proper earth wire to the icemaker.
Disconnect the main power supply before any
maintenance, repairs or cleaning is undertaken.
ENGLISH