BYTE N° 10
BYTE N° 10
BYTE N° 10
BYTE N° 11
BYTE N° 11
BYTE N° 11
BYTE N° 26
BYTE N° 26
BYTE N° 26
BIT N° 0x10
AIR TEST: command signal for opening the air circuit solenoid-valve. The
solenoid-valve stays open for the entire "command active" time.
0 = no air flow
1 = air flow
BIT N° 0x20
WIRE FORWARD: wire extension command signal. The extension speed
corresponds to the value set by the operator. Wire extension stays active
for the entire "command active" time.
0 = wire not extended
1 = wire extended
BIT N° 0x40
RESET ALARMS: reset alarms command signal.
0 = no reset operation
1 = alarms reset
BIT N° 0x01
SAVING WELDING REPORT: control signal for saving welding data into the
report (weld@net).
0 = no operation active
1 = save welding data
BIT N° 0x02
EMERGENCY: command signal for total shut-down of the welding process.
For connection to the system's safety devices.
0 = system in alarm status
1 = system operating normally
BIT N° 0x80
WIRE BRAKE: control signal for the activation of "wire brake" device.
0 = wire brake inactive
1 = wire brake active
BIT N° 0x01
PRE-GAS MODE
0=Pre-gas synergic
GAS FLOW-POST GAS
1=Fixed pre-gas
GAS FLOW-POST GAS
BIT N° 0x02
TIMING COMMUNICATION ALARM
0=0.5 s
1=5.0 s
BIT N° 0x08
JOB MODE
0=Standard
1=Job freeze
ARC STRIKING
PRE-GAS TIMING
Present
Not present
ARC STRIKING
PRE-GAS TIMING
Present
Not present
Stored job
Job
AI
Stored job
Job
Job
NO (reset)
YES
YES
YES
Called job
A+V+...
A+V+...
Called job
A+V+...
A+V+...