WAREDOSE 35
6
FILLS XXX
7
pin code 000
8
<prog ZEROdata>
9
<Y ZERO DATA? N>
10 pin change 000
0000138112
STATISTICS
In the statistics section you can read the number of fills, the count of
rinse signals, the rinse pump activation time and the chemical usage
for each pump.
While reviewing the data simply depress either the left or right buttons
to scroll through the information.
Be aware that both the Detergent and Rinse consumption data is
based on the total run time of the pumps. A mathematical formula is
used to calculate the quantity of dosed chemicals, assuming that they
have the same viscosity of water.
For tunnel machines, knowing the time needed to clean a rack, you
can easily calculate the number of washed racks, by dividing the rinse
time by this single rack time.
Once you have scrolled through all of the data, the WAREDOSE35 will
simulate a power up sequence before returning to the default display.
The available information are:
DET FILLS = number of first charges performed
RIN COUNT = number of rinsing signals received
RIN TIME = total time the S2 signal has been active
DET LITS = total quantity of Detergent dispensed according to pumps
calibration
RIN LTS = total quantity of Rinse Aid dispensed according to pumps
calibration
ENTERING THE PIN CODE
When the display shows the writing shown at the point 5 (<prog
data>), press the left button, prog, to access the programming section
and the display will change to the string shown on the left, asking for
the pin code to access the programming section. Use the left or right
buttons to enter the PIN then press the central button to confirm it.
By default, the pin code is set in factory to the value 011 but the user
can change it as described at point 11.
PROGRAMMING or CLEARING THE STATISTICS DATA
Once the correct pin code has been entered, the display will appear
as shown on the right:
Press the left button, prog, if you want to program the unit.
Press the right button ZEROdata, if you wish to clear the
collected statistics data.
CLEARING THE STATISTICS DATA
If you press the right button to choose ZEROdata, the screen will
display the question shown on the left, to ask you to confirm the
erasing of the collected data.
To confirm the zeroing of these data, you need to press left button:
this will zero out your data. The display will briefly show "done" and
then revert to the default screen.
CHANGING THE PIN CODE (HIDDEN MENU)
At point 8, if you keep pressed for 5 seconds the left button to
choose PROG, the display will change to the writing shown on the left,
giving the following possibility: here you can change the PIN CODE to
be used to access the programming section.
Press the central button to confirm the shown parameter, or use the
left / right buttons to change it before confirming it with the central
button.