FAULT
No Sensor
0.0 ft/m
0.0
V=11.6
Low Voltage
0.0 ft/m
0.0
V=7.9
Stop
0.0 ft/m
0.0
V=11.6
EV-040
ft
[1]
ft
[1]
ft
[1]
CAUSE
Though UP or DOWN keys
are pressed, the instrument
doesn't receive any signal
from the magnetic sensor
for more than 5 seconds.
The
instrument's
supply voltage is lower than
10V.
The instrument's lithium-ion
battery is discharged.
28
English
CORRECTIVE ACTION
Check the sensor electric
connections.
Check if sensor operates
properly. If not, replace it.
Check the position of
sensor and magnet on
gipsy and their distance (3
mm).
Check the operation of
electric installation or
anchor windlass.
power
Verify the charge of the
boat's battery or operation
of the electrics system.
Recharge the instrument
using the power adaptor
supplied.
While the battery is
charging the red LED of the
adaptor will remain lit.
When the LED goes off it
means the battery is fully
recharged.