Descargar Imprimir esta página

EmberGlow VFF26NLMA Manual De Instrucciones página 18

Publicidad

Idiomas disponibles

Idiomas disponibles

WARNING: You must oper-
ate this heater with the screen
in place. Make sure screen is
installed before running heater.
NOTICE: During initial operation
of new heater, burning logs will
give off a paper-burning smell.
Orange flame will also be pres-
ent. Open damper or window to
vent smell. This will only last a
few hours.
1. STOP! Read the safety information on
page 17.
2. Make sure equipment shutoff valve is fully
open.
3. Turn control knob clockwise
OFF position.
4. Wait five (5) minutes to clear out any gas.
Then smell for gas around heater and near
the floor. If you smell gas, STOP! Follow
"B" in the safety information above. If you
do not smell gas, go to the next step.
5. Turn control knob counterclockwise
to the PILOT position. Press in control
knob for five (5) seconds (see Figure 21).
Note: The first time that the heater is oper-
ated after connecting the gas supply,the
control knob should be pressed for about
thirty (30) seconds. This will allow air to
bleed from the gas system. If pilot does not
stay lit, refer to Troubleshooting, pages 22
though 25. Also contact a qualified service
technician or gas supplier for repairs. Until
repairs are made, light pilot with match.
• If control knob does not pop up when
released, contact a qualified service
technician or gas supplier for repairs.
6. With control knob pressed in, push down
and release ignitor button. This will light
pilot. The pilot is attached to the rear
of the front of burner. If needed, keep
pressing ignitor button until pilot lights.
18
OPERATION
LIGHTING INSTRUCTIONS
to the
www.sureheat.com
Note: If pilot does not stay lit, refer to
Troubleshooting, pages 22 though 25.
Also contact a qualified service technician
or gas supplier for repairs. Until repairs
are made, light pilot with match. To light
pilot with match, see Manual Lighting
Procedure, page 19.
7. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob.
Note: If pilot goes out, repeat steps 3
through 7. This heater has a safety inter-
lock system. Wait one (1) minute before
lighting pilot again.
8. Turn control knob counterclockwise
to desired heating level. The main burner
should light. Set control knob to any heat
level between HI and LO (5 and 1).
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
WARNING: If input gas
type is NG, make sure NG pilot
burner ignites. If input gas type
is LP, make sure LP pilot burner
ignites. See Figure 27, page 21.
Ignitor Button
Figure 21 - Ignitor Button and Control
Knob Locations
Control Knob
200252-01A

Publicidad

loading