en-us Electrical connection
Mount the strain relief into the 1" (25.4 mm) diameter
5.
hole in the back panel located below the terminal block.
Route the wires up through the strain relief.
Remove the green ground screw and serrated washer
6.
located beneath the terminal block.
Secure the neutral, white wire of the supply circuit to the
7.
center stud of the terminal block with a nut.
Secure the L1 (red) and L2 (black) power leads to the
8.
outside terminal studs (brass colored) with nuts.
Secure the bare copper ground lead to the range chas-
9.
sis using the green ground screw and serrated washer.
Be sure that neutral and ground terminals do not touch.
a
a
Red / L1
b
Green / ground
c
White / neutral
d
Black / L2
Tighten all connections and nuts securely.
11.
Reinstall the terminal block cover.
12.
12
c
d
b
6.4 Installing a three-wire connection
Requirements
Where local codes and ordinances permit grounding
¡
through neutral, and conversion of supply to 4-wire is
impractical, the appliance may be connected to the
power supply with a Listed (UL, CSA, ...) 3-POLE, 3-
CONDUCTOR cord kit rated 250 VOLTS, 50 AM-
PERES DEDICATED CIRCUIT, and marked for use
with ranges.
It is the responsibility of the installer to provide the
¡
proper wiring components (cord, wires, etc.) and com-
plete the electrical connection as dictated by local
codes and ordinances, and/or the National Electrical
Code.
The cord kit is required to be attached to the range ter-
¡
minal block with a strain relief which will fit a
1" (25.4 mm) diameter hole.
If not already equipped, the cord must also have
¡
¼" (6 mm) faston closed-loop lugs attached to the free
ends of the individual conductors, preferably soldered in
place.
Disconnect the electrical power at the breaker box.
1.
Locate the small bag with white jumper wire located in
2.
the literature packet.
Locate the terminal block on the rear of the appliance
3.
and remove the cover.
Remove the upper nuts only from the terminal block
4.
studs. DO NOT remove the lower nuts which secure the
range's internal wiring leads.
If applicable, remove the 4-wire power cord from the ap-
5.
pliance.
Mount the strain relief into the 1" (25.4 mm) diameter
6.
hole in the back panel located below the terminal block.
Route the wires up through the strain relief.
Secure the neutral, grounded wire of the supply circuit,
7.
to the center stud (silver colored) of the terminal block.
Secure the L1 (red) and L2 (black) power leads to the
8.
outside terminal studs (brass colored) with nuts.