Adjust detection reach
GB
The shroud (included) can be used to adjust the detection
zone to suit any specific need.
5.10
I
O
• Check to make sure the power supply is switched OFF.
• Detach sensor module from load module.
• Remove cover and lens.
• Cut shroud to size:
shrouded lens segments shorten reach.
• Fit shroud into lens.
• Fasten lens with screws.
• Fit cover ring.
• Fit sensor module onto load module.