DESCRIPTION OF PARTS in Fig. 1
1) Encoder and Motor connections terminal board
2) Connection terminal block 24 V
3) Programming LED (LD1)
4) Dip-switch for Photocell and STOP input exclusion
5) Input and antenna connection terminal board
6) Terminal block input warning LEDs. LED on =
closed input
7) Optional radio card connector
8) Control unit reset. Shortcircuiting the 2 pins for an
instant is equivalent to cutting off and restoring the
power supply
9) Dip-switch functions
10) P/P Step-by-step button
11) PROG button for Programming and Stop*
12) Trimmer for adjustment of the motor force
13) Motor speed adjustment trimmer
* This STOP button is not a safety button but serves solely to facilitate tests during installation.
FEATURES
The control unit is fitted with:
- anti-crushing system
- motor force adjustment trimmer.
- Adjustment of the motor speed
- soft start
- motor slowdown (can be cut out)
- motor brake
- magnetic limit switch sensors
- foto-test
34
14) 22/30Vac transformer secondary connection
connector
15) Power supply fuse T5A 24V
16) Sensors for magnetic end stops and warning
LEDs
17) Transformer 230/22V
18) Terminal block for 230 V connections
19) Line fuse T1A 230V
20) Radio channel 1 programming key
21) Radio channel 1 LED
22) Radio channel 2 LED
23) Radio channel 2 programming key
24) Battery charger fuse F5A 24V (optional)
25) Terminal block for battery charger connections
(optional)