TERM. No.
TERM. No.
DEVICE
L
N
Linea
T
1
Encoder
2
Encoder
3
Encoder
4
5
Motor
6/7
8/9
Auxiliares
Flasher
10
11
Indicator light /
11
12
foto-test
14
13/18
N.C. Contact
15
13/18
N.O. or N.C. Button
N.C. Button
16
13/18
17
13/18
N.O. Button
Rx Antenna
19
20
Rx Antenna
Input
Output
FUNCTION
V
I max
230Vac
1A
Power supply
Negative power supply
0Vdc
Positive power supply
5Vdc
Data
24Vdc
3A
24 V power supply
24Vdc
1A
Movement indication
24Vdc
1A
24Vdc
1A
Warning/test
Photoelectric cell
Multi-use Input
Stop button
Impulse button
Braid
Control
NOTES
Connect to 230 V line.
Heart.
The direction of movement may be reversed during programming.
Power supply for photoelectric cell or other auxiliaries.
Switches on with motor in motion. See p. 5 end 10.
With the foto-test cut out (dipswitch 8 off), this output has the function of status indicator
light with differentiated blinking. If the foto-test function is used, the indicator light (without
blinking) may be connected in parallel.
During closing the gate reverses direction. If it is not used, put dip 1 of part. 4 in the ON
position.
See table 2, functions 3 and 4.
Blocks all functions. If it is not used, put dip 2 of part. 4 in the ON position.
See table 2, functions 1 and 2.
for the type of antenna to be used, refer to receiver instructions.