Setting the Jumpers Without Circuit
Board
NOTE: The following procedures must be
performed by a qualified electrician familiar
with the construction and operation of this type
of machinery.
1. Disconnect power to the machine.
2. Unlock and raise the top cover.
3. Remove the control module cover.
4. The mechanical timer is located in the middle of
the control module. The odd-numbered side of
the timer is used to change the duration of
individual cycle steps. Refer to Figure 2.
Eleven possible jumper configurations are
available for changing the cycle time. Refer to
Table 3.
Jumper Setting
None
1a to 3a
1a to 3a to 3b
1a to 3a to 3b to 5b
1a to 3a to 5a*
1a to 3a to 5a to 5b
1a to 3b
1a to 3b to 5b
1a to 5a
1a to 5a to 5b
1a to 5b
*Factory Setting
F232133
Mechanical Timer Cycle Time Options
PreWash
Wash
4
8
4
4
--
4
--
4
2
4
2
4
--
8
--
8
2
8
2
8
4
8
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
19b
17b
15b
13b
11b
9b
7b
5b
3b
1b
Rinse 1
Rinse 2
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
Table 3
Programming
19
19a
17
17a
15
15a
13
13a
11
11a
9
9a
7
7a
5
5a
3
3a
1
1a
Figure 2
Final
Rinse 3
Spin
1.5
4
1.5
4
1.5
4
1.5
2
1.5
4
1.5
2
1.5
4
1.5
2
1.5
4
1.5
2
1.5
2
Cycle
Time
27.5
23.5
18.5
16.5
21.5
19.5
22.5
20.5
25.5
23.5
25.5
9

Publicidad