Compressors with vessel(s):
20
Vessel 1
21
Vessel 2
22
Ball valve at condensate drainage point
1
23
Ball valve at condensate drainage point
2
24
Ball valve at condensate drainage point
3
25
Safety valve on vessel 1
26
Safety valve on vessel 2
27
Pressure gauge on vessel 1
28
Pressure gauge on vessel 2
29
Ball valve 1 (inlet on vessel 1)
30
Ball valve 2 (outlet on vessel 1)
31
Ball valve 3 (inlet on vessel 2)
32
Ball valve 4 (outlet on vessel 2)
33
Compressed air outlet
34
Safety tub
35
Compressed air cold dryer
36
Bypass line
8
Commissioning
8.1
Conditions at the installation loca-
tion
• Rooms: as dust-free as possible, dry, well
ventilated.
• Installation surface: flat, horizontal.
• Keep heat dissipating devices and lines
away from the compressor.
Compressors with vessel(s):
• When installing the vessel, make sure that
all sides can be viewed clearly and internal
checks made unhindered.
• Type plate easily visible.
8.2
Installing the compressor
1. Lift the compressor using a fork-lift
truck.
2. Screw rubber dampers to the feet of the
compressor or vessel. Do not forget to
insert washers! Tighten nuts to 80 Nm.
3. Transport the compressor to the place of
installation.
2. Does not apply for AM x-10 E1 180 (DK
z).
8.3
Before first use
1. Carry out a visual inspection.
2. Establish the electrical connection.
3. Check the oil level (see Chap. 10.3).
4. Attach the rubber dampers (see Chap.
8.2).
8.4
Electrical connection
Have a trained and qualified electrician per-
form the following tasks:
• The mains voltage must match that speci-
fied on the rating plate.
• Electric protection according to technical
data.
• Install the connection cable (not included
in scope of supply)!
Cable: min. cross section 2.5 mm², max.
cable length 10 m.
8.5
Compressed air bleeding
Connect the elastic connecting hose between
the compressed air outlet and compressed
air pipe system.
8.6
Starting up the compressor
1. Switch on the main switch. The version
and serial number are displayed.
2. If the direction of rotation is incorrect
switch off the compressor at the main
switch and change the phases at the
connection.
9
Operation
9.1
Starting the compressor
1. Press button T1 to start the compressor.
2. The compressor starts up and switches
to a star connection if the pressure is
lower than the switch-on pressure after
the initialisation time.
3. After 5 s, the compressor switches to a
delta connection.
GB
AM x-10 E1
3

Publicidad

loading