Hazardous Area Installations
(Reference European ATEX Directive 94/9/EC, Annex II, 1/0/6)
The following instructions apply to equipment covered by certificate number
SIRA06ATEX9305X:
1.
For use and assembly, refer to the main instructions.
2.
The equipment is certified for use as Category 2D equipment and may be used in
hazardous zones 21 and 22 with dusts.
3.
This equipment has a maximum surface temperature of T90 °C (in a 75 °C ambient).
Refer to the applicable code of practice for selection of this equipment with respect
to specific dust ignition temperatures.
4.
The equipment is certified for use in an ambient temperature range of -40 °C to
75 °C.
5.
If the conductors of the attached cable are terminated in the hazardous area,
appropriate explosion protection ('Ex') methods should be used that meet the
requirements of European Directive 94/9/EC for Group II, Category 2D.
6.
The equipment has not been assessed as a safety related device (as referred to by
Directive 94/9/EC Annex II, clause 1.5).
7.
Installation and inspection of this equipment shall be carried out by suitably trained
personnel in accordance with the applicable code of practice.
8.
Repair of this equipment shall be carried out by suitably trained personnel in
accordance with the applicable code of practice.
9.
Components to be incorporated into or used as replacements in the equipment shall
be fitted by suitably trained personnel in accordance with the manufacturer's
documentation.
Page EN-10
Milltronics MSI/MMI – QUICK START MANUAL
7ML19985XK81