6. TROUBLESHOOTING
This produce complies with the relevant regulations governing the safety of electrical equip-
ment. For safety reasons, any technical inspections or repairs must be performed by qualified
staff, to prevent all hazards for the user.
If the appliance does not work, before calling the After-Sales Service, to avoid unnecessary
expense, check yourself that the operations listed in this troubleshooting table have been car-
ried out..
1
Appliance does not start
2
No water filling
3
No water visible in washing
drum
4
Water not pumped out
5
Water not pumped out after
last rinse in delicate fabrics
and wool wash programmes
6
Water takes in and pumps out
water continually
7
Strong
vibrations
spins
8
Too much foam formed in
tank and flowing out of draw-
er
9
Water on floor
10
Not all fabric conditioner used
or too much water left in
compartment
Check that:
- plug is properly connected to socket
- door is securely closed
- "Start/Pause" button has been pressed.
Check that:
-
plug is properly connected to socket
-
door is securely closed
-
water tap is turned on
-
water intake hose filters not fouled.
-
water intake hose not trapped or kinked.
No malfunction.
The water level is below the level of the glass in the door because
new appliances use very little water to achieve the same washing
and rinsing results.
Check that:
-
drain hose is not kinked
-
drain pump not fouled.
It is not a malfunction: pause programmed into washing programme
to prevent creasing of fabrics.
To pump out water, proceed as described in "Programme End" point.
Check that end of drain hose is not too low down.
during
Check that:
-
Appliance is properly levelled
-
washing machine not too close to walls or kitchen units
-
internal unit on flexible mounts locked in position.
Check that:
detergent used is recommended for automatic washing ma-
-
chines and not for hand washing
-
quantity used is as stated in manual and no more
Check that:
water intake hose fittings not loose
-
end of drain hose still correctly positioned.
-
Check that detergent drawer siphons are correctly fitted and not
fouled.
EN