7.2 Working time
The setting of this dip enables to choose between a working time manually set through a trimmer or an infinite working time.
ON
An infinite working time is set, the output remains activated till the reception of a stop or an opposite motion impulse.
OFF
ON
The working time is manually set through the "Run Timer" trimmer adjustment (see paragraph 6).
OFF
7.3 Pulse operation
The setting of this dip configures the operating mode, when the dip 1 and the dip 2 are set on ON (pulse operation).
ON
The "Go functioning" is activated. The automation works under "step by step" mode with one button. The UP button
OFF
makes the sequence open -stop-close. While the stop can be obtained pressing the button DOWN (or STOP in case of
a 3 buttons transmitter).
ON
The open– close function with two buttons is activated . Pressing the button UP the automation closes, a further closing
impulse ( or stop) stops the automation, pressing the button DOWN the automation starts closing.
OFF
The "GO" function is automatically excluded with the dip 1 and/or the dip 2 set on ON.
8. Working time adjustment
It enables to set the operation time of the automation. The time can be set for values between 1,5 seconds and 90 seconds.
The working time is excluded in case that the dead man function is activated.
Turn clockwise the "Run Time" trim-
mer to increase the working time.
-
+
RUN TIMER
9. Safety devices intervention
The intervention of the safety devices changes accordingly the function setting of the control unit. In particular:
DIP POSITION:
Automation on opening : the intervention of the photocell is ignored.
Automation on closing: the intervention of the photocell stops and inverses the movement of the automation.
DIP POSITION:
6-1622606
rev.0
10/05/2013
Turn counter clockwise the "Run Time"
trimmer to decrease the working time.
Automation on opening: the intervention of the photocell is ignored.
Automation on closing : the intervention of the photocell stops the movement of the automation.