dirt may collect on the laser window. Remove any
moisture or dirt with a soft, dry cloth.
DO NOT use aggressive cleaning agents or solvents.
NOTE: Store the laser tool in its case when not in use.
If storing for extended time, remove batteries before
storage to prevent possible damage to the instrument.
Warranty
Two Year Warranty
Stanley warrants its electronic measuring tools against
deficiencies in materials and / or workmanship for two
years from date of purchase.
Deficient products will be repaired or replaced,
at Stanley's option, if sent together with proof of
purchase to your local dealer. This Warranty does
not cover deficiencies caused by accidental damage,
wear and tear, use other than in accordance with the
manufacturer's instructions or repair or alteration of
this product not authorised by Stanley.
Repair or replacement under this Warranty does not
affect the expiry date of the Warranty.
To the extent permitted by law, Stanley shall not be
liable under this Warranty for indirect or consequential
loss resulting from deficiencies in this product.
This Warranty may not be varied without the
authorisation of Stanley.
Specifications
Multi-Line Lasers
Performance
Working Distance
Wavelength
Operation Time (All Laser lines on)
Horizontal Accuracy:
Vertical Accuracy:
Laser Class
Vertical Beam Fan Angle:
Horizontal Beam Fan Angle:
Temperature Range (Operating)
Temperature Range (Storage)
IP Rating
This Warranty does not affect the statutory rights of
consumer purchasers of this product.
This Warranty shall be governed by and construed in
accordance with the laws of the country sold where
in and Stanley and the purchaser each irrevocably
agrees to submit to the exclusive jurisdiction of the
courts of that country over any claim or matter arising
under or in connection with this Warranty.
Calibration and care are not covered by warranty.
NOTE: The customer is responsible for the correct use
and care of the instrument. Moreover, the customer
is completely responsible for periodically checking
the accuracy of the laser unit, and therefore for the
calibration of the instrument.
Subject to change without notice.
4V360H Red Beam
STHT77521 / STHT77522 / STHT77523
10 m
Vertical, Horizontal, & Down:
630 ~ 680 nm
4*AA ≥ 4 hrs
4V360H Green Beam
STHT77524 / STHT77525 / STHT77526
Vertical & Horizontal: 510 ~ 530 nm
Down: 630 ~ 680 nm
4*AA ≥ 2 hrs
H ≤ ± 4 mm / 10 m
V ≤ ± 4 mm / 10 m
2
> 110°
< 360°
-5°C ~ +45°C
-20°C ~ +50°C