Mounting
• Mount the machine along the rear channels.
• Insert the electric ducting through the hole next to the terminal strip.
• Use the drill template provided to fix the dryer to the wall.
• Drill 4 holes with a diameter of 8 mm(5/16"),
and take care to clean all traces of dust from the holes.
• Screw down the base firmly to the wall using a flat
ended screwdriver of 6 -7mm (1/4").
• Connect the electric ducting to the terminal strip.
Screw down the 3 locking screws firmly.
Means for disconnection of the mains should be predicted, with a contact separation at
least 3 mm (0.12") in all poles. The mentioned means of disconnection must be
incorporated in the fixing wiring.
ADJUST DETECTING DISTANCE
The hand dryer has means to adjust manually
the distance for detecting hands.
These adjustments of the motor
speed must be made by a qualified technician only.
The adjustments can be made by
moving the cursor of the linear potentiometer.
METHOD OF USE
To dry hands correctly, we recommend rising well to remove all traces of soap.
Automatic models:
These models operate by hand detection. If hands are held 10-15 cm (3,9-5,9") from the air
outlet, the dryer will start working. Immediately after the hands can be gradually taken away
from the dryer and will continue drying up to a maximum distance of 15-20 cm (5,9-7,9"). The
machine stops will stop 2-3 seconds after use. If the sensor isblocked due to vandalism, the
dryer will completely stop working.
Please let a minimum separation of 40 cm (15,75") between appliance and any shelf,
marble, worktop or washbasin.