CONTROL PANEL - LEDS (FIG.14)
L1. Setting of current adjustment by remote
control.
L2. Setting of current adjustment from the
front panel.
L3. Setting of visualization of welding volta-
ge on the display.
L4. Setting of visualization of welding current
on the display.
L5. Set welding procedure: LED lights in
TIG, in CV lights simultaneously with L6.
L6. Set welding procedure: LED lights in
MMA, in CV lights simultaneously with
L5.
L7. When on it indicates 2T mode, fl ashing
indicates 2T mode with pulse.
L8. When on it indicates 4T mode, fl ashing
indicates 4T mode with pulse.
L9. Welding parameter adjustment, with
knob 2 (red LED on).
L10. VRD function activated in MMA (red LED
on).
L11. Power voltage present (green LED on)
L12. Thermal protection intervention (yellow
LED on)
Note: With the system in H2O confi gura-
tion, the yellow LED will start fl ashing to
warn of insuffi cient cooling fl uid pressu-
re/fl ow and the welding process will be
interrupted.
WARNING: When the yellow LED is
on, do not cut off power from the cur-
rent generator, as this would interrupt
ventilation to the overheated parts.
When the LED goes off, the welding
process may continue.
L11
L1
L2
L3
L4
L14
L22
L25
L21
L24
L23
L20
L26
L31
L19
L13
L5
L12
L7
L18
L16
L15
L17
L9
L27
L28
L29
Fig.14
L13. VRD
L14. On indicates that the display is display-
ing a value in Ampere.
L15. On indicates that the display is display-
ing a value in volts.
L16. On indicates that the display is showing
a percentage value.
L17.On indicates that the display is showing a
value in seconds.
L18. ON indicates that the display is showing
a value in Hz.
L19. Pregas time adjustable with knob 2, "Aut"
- 0.0 ÷ 20.0 ".
L20. HF starting current adjustable with knob
2, "Aut" or from 5A to Imax (A) or from 10
to 150% of Iweld.
L21. Time of gradual current increase (up-slo-
pe), adjustable with knob 2, "Aut" or from
0.0 to 25.0".
L22. Hs/Af: Hot start function (red LED on +
letter H on the display) / Arc force fun-
ction (red LED fl ashing + letter A on the
display); these values can be adjusted
using the knob 2.
L23. Second level current, adjustable using
the knob 2, OFF-5÷Imax. Only on 4T.
L24. Duration in percentage of the peak cur-
rent with respect to the pulsation period,
adjustable with the knob 2 from 10% ÷
90%.
L25. Pulse frequency of the arc, 0.1 ÷ 4500Hz;
value adjustable with the knob 2.
L26. Minimum pulsation current adjustable
with knob 2, from 5A to Iweld (A) or from