JAM CLEARING PROCEDURE
Disconnect tool from air supply before making adjustments or before attempting any part
assembly or disassembly.
On occasion nails can jam in the nose of a pneumatic nailer. This can be caused by striking a metal plate in
the wall, drywall screw, or some other hard object. The DA1564K feature open drive channel architecture for
jam clearing. To clear a jam follow this procedure:
1. Disconnect the tool from the air supply.
2. Release the pusher so it is no longer applying force to the nail sticks.
3. Open the jam clearing nose door by pulling down and then up on the latch.
4. Remove the jammed fastener. In certain circumstances, pliers may be required to remove the fastener.
5. Close the jam clearing nose door latch.
6. Pull nail pusher back behind nail sticks.
DA1564K JAM CLEARING
1
4
2
5
-12-
3
6