enGlisH
SENSOR
COM
1
ON
OFF
RAIN SENSOR
Figure 19: Sensor Override Switch
SENSOR
COM
1
2
3
4
ON
OFF
RAIN SENSOR
Figure 20: Connecting the Rain Sensor
25
2
3
4
5
6
PUMP
24VAC
5
6
PUMP
24VAC
pump start relay
A Pump start relay can be connected to the controller . The purpose of the
pump start relay is to synchronise your pump for watering with your sprinkler
controller .
Connecting a pump start relay
Connect the sprinkler controller wires to the controller by connecting one wire
to the terminal labeled "Pump" or "Master Valve" . The other wire should be
connected to the terminal label "Com" or "Common" .
trouble shooting
problem/possible Causes
one or more valves do not turn on:
1 . Faulty solenoid .
2 . Wire broken or not connected .
3 . Flow control stem screwed down, shutting valve off .
4 . Programming is incorrect .
stations turn on when they are not supposed to:
1 . Water pressure is too high .
2 . More than one start time is programmed .
26