4) Obstruction force adjustment
Decrease Force
5) Automatic closing
Auto Close enabled
Auto Close disabled
Opening your life
CAUTION: the obstruction force adjustment is set automatically during
programming. Normally no adjustment is necessary.
a) Press and hold the SET button until 3 appears on the display then release
the button.
The unit is now in force adjustment mode.
b) Press the UP button to increase the force setting or the DOWN button to
decrease the force setting.
The minimum force is 1 and it can be adjusted upward.
c) Press SET to con rm your setting
NOTE: The force is set on 3 as standard in factory.
NOTE: We recommend that Safety Photo Beams be used in any installa-
tion where the Auto Close function is enabled.
Increase A/C time
a) Press and hold UP button until a horizontal bar is indicated on the
display. Now press UP button once to set the auto close time (in minutes).
b) Press UP button to increase the time, or DOWN button to decrease the
Increase A/C time
time.
The Maximum time is 135 seconds. To disable Auto Close, set time to zero
(0).
c) Press SET button to con rm the set.
Opening your life
10
Raptor
RP120
Code:
www.accessmatic.com