Contents Description
Comfort burner on time (b01=1)
Not implemented (b01=2)
b10
Not implemented (b01=3)
Not implemented (b01=4)
Flowmeter timing (b01=1)
Storage tank preparation mode (b01=2)
b11
Flowmeter timing (b01=3)
Storage tank preparation mode (b01=4)
Modulation delta (b01=1)
Priority override - Activation (b01=2)
b12
Modulation delta (b01=3)
Priority override - Activation (b01=4)
Not implemented (b01=1)
Priority override - Deactivation (b01=2)
b13
Not implemented (b01=3)
Priority override - Deactivation (b01=4)
b14
Pump antiblock operation time
Flowmeter type selection (b01=1)
No effect on adjustment (b01=2)
b15
Flowmeter type selection (b01=3)
No effect on adjustment (b01=4)
b16
Fan frequency in standby mode
b17
Summer/Winter symbol
DHW mode activation flow rate (b01=1)
No effect on adjustment (b01=2)
b18
DHW mode activation flow rate (b01=3)
No effect on adjustment (b01=4)
DHW mode deactivation flow rate (b01=1)
No effect on adjustment (b01=2)
b19
DHW mode deactivation flow rate (b01=3)
No effect on adjustment (b01=4)
b20
Flue material selection
b21
PVC flue maximum temperature
b22
CPVC flue maximum temperature
Standard flue shutdown maximum tempera-
b23
ture
b24
PVC flue shutdown maximum temperature 60-110°C
CPVC flue shutdown maximum tempera-
b25
ture
Flow temperature limit in automatic calibra-
b26
tion
Maximum temperature during calibration in
b27
DHW mode
b28
Flowmeter sensitivity factor
b29
Restoring Factory Values
P30
Heating ramp
Virtual setpoint min. temperature (b01=1)
Virtual setpoint min. temperature (b01=2)
P31
Virtual setpoint min. temperature (b01=3)
Virtual setpoint min. temperature (b01=4)
P32
Heating standby time
P33
Heating Post-Circulation
178
BLUEHELIX PRO RRT 24 C
Range
0-40 seconds
--
--
--
0=Deactivated, 1-10=seconds
0=Fixed primary, 1=Linked to setpoint, 2=Ramp
0=Deactivated, 1-10=seconds
0=Fixed primary, 1=Linked to setpoint, 2=Ramp
0-30°C/10
0-255 minutes
0-30°C/10
0-255 minutes
--
0-255 minutes
--
0-255 minutes
0-20 seconds
0=Flow. (450 imp/l), 1=Flow. (700 imp/l), 2= Flow. (190
imp/l)
0=Flow. (450 imp/l), 1=Flow. (700 imp/l), 2= Flow. (190
imp/l)
0=Flow. (450 imp/l), 1=Flow. (700 imp/l), 2= Flow. (190
imp/l)
0=Flow. (450 imp/l), 1=Flow. (700 imp/l), 2= Flow. (190
imp/l)
0-100%
0 = Disabled, 1 = Enabled
0-100L/min/10
0-100L/min/10
0-100L/min/10
0-100L/min/10
0-100L/min/10
0-100L/min/10
0-100L/min/10
0-100L/min/10
0=Standard, 1=PVC, 2=CPVC
60-110°C
60-110°C
60-110°C
60-110°C
25°C ÷ 55°C
75°C ÷ 95°C
0 ÷ 60 (0 = disabled)
Change the value from 0 to 10 by pressing the "DHW +"
button. Confirm by pressing the "heating +" button.
1-20°C/minute
0=Deactivated, 1-80°C
0=Deactivated, 1-80°C
0=Deactivated, 1-80°C
0=Deactivated, 1-80°C
0-10 minutes
0-255 minutes
cod. 3541Q530 - Rev. 00 - 10/2018
Default
15 seconds
--
--
--
0=Deactivated
0=Fixed primary
0=Deactivated
0=Fixed primary
0°C/10
30 minutes
0°C/10
30 minutes
--
15 minutes
--
15 minutes
5 seconds
2= Flowmeter (190 imp/
l)
2= Flowmeter (190 imp/
l)
2= Flowmeter (190 imp/
l)
2= Flowmeter (190 imp/
l)
0%
0 = Disabled
25
25
25
25
20
20
20
20
0=Standard
88°C
93°C
100°C
93°C
98°C
30°C
80°C
20
-
4°C/minute
0=Deactivated
0=Deactivated
0=Deactivated
0=Deactivated
4 minutes
15 minutes
EN