Descargar Imprimir esta página

Ferroli BLUEHELIX PRO RRT 24 C Instrucciones De Uso, Instalación Y Mantenimiento página 187

Publicidad

Idiomas disponibles

Idiomas disponibles

BLUEHELIX PRO RRT 24 C
Circulating pump
Before carrying out the following instructions it is advisable to protect the room and the boiler's electrical box
A
against accidental water spillage.
1
2
fig. 37
Disconnect the power supply and turn off the gas cock ahead of the valve.
Electrically disconnect the circulating pump, releasing the connections by raising detail "1" of fig. 37.
Drain the water in the boiler (see "System draining" on page 161).
Unscrew and remove the circulating pump motor assembly (fig. 39)
EN
fig. 38
cod. 3541Q530 - Rev. 00 - 10/2018
fig. 39
187

Publicidad

loading