Replacing the water pressure switch
Before carrying out the following instructions it is advisable to protect the room and the boiler's electrical box
A
against accidental water spillage.
Disconnect the power supply and turn off the gas cock ahead of the valve.
Drain the water from the heating circuit.
Remove the connector "1" and the fastening clip "2".
Remove the water pressure switch "3".
Cleaning or replacing the flowmeter
Before carrying out the following instructions it is advisable to protect the room and the boiler's electrical box
A
against accidental water spillage.
5
4
Disconnect the power supply and turn off the gas cock ahead of the valve.
Close the cold water inlet and turn on the DHW system faucets
Release the fork "4" and remove the flowmeter assembly "5".
The flowmeter components can thus be cleaned (see fig. 47 and fig. 48) or replaced.
192
fig. 46- Flowmeter
cod. 3541Q530 - Rev. 00 - 10/2018
BLUEHELIX PRO RRT 24 C
3
1
2
fig. 45
1 - Flow limiter
2 - Fan
3 - Filter
4 - Clip
5 - Flowmeter