Contents Description
Comfort2 standby time (b01=1)
Not implemented (b01=2)
P50
Not implemented (b01=3)
Not implemented (b01=4)
Solar deactivation temperature (b01=1)
Setpoint deltaT (b01=2)
P51
Solar deactivation temperature (b01=3)
Setpoint deltaT (b01=4)
Solar ignition temperature (b01=1)
DHW ramp (b01=2)
P52
Solar ignition temperature (b01=3)
DHW ramp (b01=4)
Solar standby time (b01=1)
No effect on adjustment (b01=2)
P53
Solar standby time (b01=3)
No effect on adjustment (b01=4)
Heating deltaT temperature adjustment
(b01=1)
Heating deltaT temperature adjustment
(b01=2)
P54
Heating deltaT temperature adjustment
(b01=3)
Heating deltaT temperature adjustment
(b01=4)
Primary exchanger protection temperature
(b01=1)
Primary exchanger protection temperature
(b01=2)
P55
Primary exchanger protection temperature
(b01=3)
Primary exchanger protection temperature
(b01=4)
P56
System min. pressure value
P57
System nominal pressure value
Exchanger protection intervention (b01=1)
Exchanger protection intervention (b01=2)
P58
Exchanger protection intervention (b01=3)
Exchanger protection intervention (b01=4)
P59
Heating hysteresis after ignition
P60
Timer for heating hysteresis after ignition
Pump deactivation with OpenTherm
P61
(ATTIVE ONLY WITH FW 3)
Notes:
1. Parameters with more than one description vary their function and/or range in relation to the setting of the parameter
given in brackets.
2. Parameters with more than one description are reset to the default value if the parameter given in brackets is mo-
dified.
3. The Maximum Heating Power parameter can also be modified in Test Mode.
Press the Reset button to return to the Service Menu. Press the Reset button for 20 seconds to exit the card Service
Menu, or exiting occurs automatically after 15 minutes.
180
BLUEHELIX PRO RRT 24 C
Range
0-100 minutes
--
--
--
0-100°C
0-20°C
0-100°C
0-20°C
0-100°C
1-20°C/minute
0-100°C
1-20°C/minute
0-255 seconds
0-255 seconds
0-255 seconds
0-255 seconds
0-60°C
0-60°C
0-60°C
0-60°C
0-150°C
0-150°C
0-150°C
0-150°C
0-8bar/10 (Only for boilers with water pressure sensor)
5-20bar/10 (Only for boilers with water pressure sensor)
0=No F43, 1-15=1-15°C/second
0=No F43, 1-15=1-15°C/second
0=No F43, 1-15=1-15°C/second
0=No F43, 1-15=1-15°C/second
6-30°C
60-180 seconds
0-1
cod. 3541Q530 - Rev. 00 - 10/2018
Default
42 minutes
--
--
--
10°C
0°C
10°C
0°C
10°C
5°C/minute
10°C
5°C/minute
10 seconds
0 seconds
10 seconds
0 seconds
18°C
18°C
18°C
18°C
43°C
43°C
43°C
43°C
4 bar/10
7 bar/10
10°C/second
10°C/second
10°C/second
10°C/second
10°C
60 seconds
0
EN