CAUTION! HOT WHILE IN OPER-
WARNING
ATION. DO NOT TOUCH. KEEP
CHILDREN, ANIMALS, CLOTHING AND COM-
BUSTIBLES AWAY FROM HEATER.
Keep all combustible materials, gasoline, and other
flammable vapors and liquid away from this heater.
Minimum Clearance From Combustibles
Sides
Top
3 ft.
5 ft.
For installation on combustible flooring as a free
standing unit with the following minimum clearances
from combustible construction:
Top:
5 ft.
Front: 5 ft.
Rear: 3 ft.
Floor: Combustible
It is the owner's responsibility to communicate
combustible clearances with others.
For use with propane (LP)
WARNING
gas only.
DO NOT use any LP cylinder
WARNING
larger than 20 lbs.
ALWAYS install the heater so that it is not directly
exposed to water spray, rain, dripping water, or wind.
ALWAYS provide adequate clearance for accessibility,
combustion and ventilation (air supply) while heater is
operating.
– Use heater in accordance with all local codes.
In the absence of local codes, refer to The
National Fuel Code, ANSI Z223.1.
– This heater is shipped from the factory
for use with propane (LP) gas only. Do not
convert to any other gas. Installation must
conform to local codes, or in their absence,
with the standard for the Storage and Handling
of Liquefied Petroleum Gases ANSI/NFPA 58
and the Natural Gas and Propane Installation
Code CSA B149.1.
RISK OF FIRE! ALWAYS ATTACH THE HEATER IN AN UPRIGHT VERTICAL
WARNING
POSITION. ALWAYS LOCATE HEATER ON A STABLE AND LEVEL SURFACE!
© 2020 Pinnacle Climate Technologies, Inc.
All manuals and user guides at all-guides.com
WHILE BURNING OR WHILE CONNECTED
SAFETY INFORMATION
Front
Rear
5 ft.
3 ft.
Sides: 3 ft.
NEVER LEAVE HEATER UNATTENDED
TO A FUEL SOURCE
The hose assembly shall be
WARNING
pro tected from traffic, building
material and contact with hot surfaces both
during use and while in storage.
– Gas supply connections should be checked by
using a 50/50 soap and water solution. Never
use a flame to check for gas leaks.
– Do not direct heater discharge towards the LP
cylinder unless it is at least 20 feet from the
heater.
– Use only the regulator and hose assembly
provided with this heater. Inspect the
regulator/hose assembly prior to each use
of the heater. If there is excessive abrasion
or wear, or if the hose is cut, replace it with
the proper assembly shown in the parts list
following manufacturer's specification, prior to
using the heater.
Minimum and Maximum Inlet Pressure
PT-16-TTC
Min.
Max.
Propane Tank Top Heater User's Manual
5
PT-32-TTC
25 PSI
200 PSI