Field Wiring
Service Box
Green LED
Diagnostic Light
Control
Cable Input
10-1/4"
(26 cm)
3/4"
(1.9 cm)
3. Determine the Location of the Steam Generator
IMPORTANT! The minimum required access panel is 24" (61 cm) L x 15" (38.1 cm) H. Allow for a
minimum 12" (30.5 cm) space around all sides of the steam generator. Allow for 3/4" (1.9 cm) space
between the generator and the drain pan.
Ensure clearance between the steam line and any surrounding surfaces.
Allow for access to the steam generator after installation.
Allow for a 12" (30.5 cm) air gap on all sides of the generator.
Allow for a drain or spill pan.
For optimum performance, install the steam generator below the level of the steam head and as
close as possible to the steam head. The steam generator should be installed within 25 ft (7.62 m) of
the steam head in a dry, well-ventilated area
4. Install the Electrical Supply
Model
K-1652 , K-1695
Ordering Information
Required Electrical Service
Generator -
5 kW, 240 V 40 A,
Dedicated
50/60 Hz
Circuit Required
Product Information
Weight
21 lbs (9.5 kg)
Electrical Rating 240 V, 27 A, 60 Hz
Kohler Co.
17-5/8" (44.8 cm)
19-11/16" (50 cm)
Inside surface of Drain/Spill Pan
K-1657, K-1708
7 kW, 240 V, 50 A,
50/60 Hz
21 lbs (9.5 kg)
240 V, 36 A, 60 Hz
3/8" NPT Water In
Minimum required access panel is
24" (61 cm) L x 15" (38.1 cm) H.
Allow for a minimum of 12" (30.5 cm) of
space around all sides of the steam generator.
Allow for 3/4" (1.9 cm) space between the
generator and the Drain/Spill Pan.
3/4" NPT
Pressure Relief
1/2" NPT
Steam Outlet
12-1/2"
(31.8 cm)
K-1658, K-1733
9 kW, 240 V, 60 A,
50/60 Hz
21 lbs (9.5 kg)
240 V, 45 A, 60 Hz
7
3/8" NPT Drain
6-1/8" (15.6 cm)
K-1659, K-1734
11 kW, 240 V, 60 A,
50/60 Hz
21 lbs (9.5 kg)
240 V, 46 A, 60 Hz
1060226-2-G