Maintain a 12" (30.5 cm) space around the unit.
5. Install the Steam Generator
WARNING: Risk of property damage. Allow a minimum of 12" (30.5 cm) of air space around the
steam generator at all times. This provides an area for the heat generated by the unit to dissipate.
NOTICE: For optimum performance, install the steam generator as close as possible to the steam head.
The steam generator must be installed within 25' (7.62 m) of the steam head.
Install the desired drain pan at the steam generator location.
IMPORTANT! The support blocks should be constructed of heat resistant material.
Position support blocks so the steam generator will have 3/4" (1.9 cm) of clearance from the drain
pan.
Position the steam generator on the support blocks.
Kohler Co.
Control Cable
Input
3/4" (1.9 cm) Min
Drain Pan
Steam Outlet
Pressure Relief Valve
Inlet
Drain (install per
applicable codes.)
9
1060226-2-G