GB
4
INSTALLATION
The installation must be carried out by a professional.
WARNING
When welding in an environment with increased electrical danger, only power
sources intended for this environment may be used. These power sources are
marked with the symbol
4.1
Lifting instructions
CAUTION
Mounting a large (Ø 440 mm) bobbin change the gravity and tipping and
crushing hazard exists when lifting. Protect yourself and warn bystanders
of the risk!
To avoid personal injury and / or equipment damage, lift using method and
attachment points shown here.
Ordering number for the lifting eye can be found on page 50.
Note! If another mounting device is used, this should be insulated from the wire feed
unit.
bm55d1e
- 36 -
© ESAB AB 2013