Some LP tanks have differing top collar assemblies . (The top collar is the metal protective
ring around the valve .) One series of tanks mount with the valve facing front (1) . The other
tanks mount with the valve facing away from the fuel scale (2) . Weber recommends
Manchester or Worthington tanks with a 47 .6 lb water capacity . Other tanks may be
acceptable for use with the appliance provided they are compatible with the appliance
retention means (see illustrations) .
The LP tank is installed inside the tank enclosure, on the tank scale (left side) .
A) Loosen tank lock wing nut . Swing tank lock up (3) .
B) Turn the LP tank so the opening of the valve is either to the front or side of the
Weber
gas grill .
®
C) Lift tank up into position on the tank scale (4) .
D) Swing the tank lock down . Tighten the wing nut .
Connect The Hose To The Tank
A) Remove the plastic dust cover from the valve .
B) Screw the regulator coupling onto the tank valve, clockwise, or to the right . Hand-
tighten only (5) .
Note: This connection tightens clockwise and will not allow gas to flow unless the
connection is tight. The connection requires tightening by hand only.
m WARNING: Do not use a wrench to tighten the connection.
Using a wrench could damage the regulator coupling and
could cause a leak.
◆
10
GAS INSTRUCTIONS
1
3
2
3
4
5