5.7 Final operations for gas appliances
After making the adjustment described above, reassemble the appliance,
reversing the procedures described in point "Changing the hob nozzles".
After adjusting for use of a gas other than the gas used for testing the
appliance, replace the gas setting label inside the warming
compartment with the label for the new gas. The label is available
from your nearest Authorized Service Centre.
5.7.1 Regulation of minimum for natural gas
Light the burner and turn it to the minimum setting. Remove the knob and
adjust the regulator screw inside or beside the tap rod (depending on the
model) until an even minimum flame is obtained. Put the knob back in place
and check the stability of the burner flame (the flame must not go out when
the knob is minimum setting). Repeat the operation on all the gas taps.
5.7.2 Regulation of minimum for LPG
To regulate the minimum for LPG, fully tighten the screw inside or next to the
gas tap pin (depending on the model) in a clockwise direction. The diameters
of the by-passes for each burner are given in table "Burner and nozzle
characteristics table".
5.7.3 Lubrication of gas taps
With time it may happen that the gas taps get blocked and hard to turn. Clean
them inside and re-grease them. This operation must be done by an
authorized person.
5.7.4 Greasing the gas taps
Over time, the gas taps may become stiff or jam. Clean their insides and
change their lubricating grease. The operation must be carried out by a
skilled technician.