3.4 Troubleshooting
Fault Diagnosis
The boiler is equipped with an advanced self-diagnosis system. In the event of trouble with the boiler, the 3 LEDs
will indicate the code of the fault.
There are faults that cause shutdown: in order to restore operation it suffices to turn the selector (ref. 3 - fig. 1)
onto RESET for 1 second and then back onto
remote timer control if this is installed; if the boiler fails to start, it is necessary to resolve the fault indicated by the
operating LEDs.
Other faults cause temporary shutdowns that are automatically reset as soon as the value comes back within the
boiler's normal working range.
Fault
No burner
ignition
Overheating protection
trips
Flame present with burner
off signal
Air pressure switch
(fails to close the contacts
within 60 sec. of turning on
the fan)
Low system
pressure
Delivery sensor fault
Tap water sensor fault
Exchanger protection trips.
(The LEDs blink alternately)
LED key
(summer) or onto
Red
Green
On
Off
Cod. 3540D952 - 11/2008 (Rev. 00)
(winter) or with the RESET on the optional
Possible cause
Yellow
• No gas
• Detection/ignition
electrode fault
• Defective gas valve
• Ignition power
too low
• Heating sensor
damaged
• No circulation
of water in the system
• Air in the system
• Electrode fault
• Card trouble
• Air pressure switch contact
open
• Incorrect wiring
to the air pressure switch
• Wrong diaphragm
• Flue not correctly
sized or obstructed
• System empty
• Water pressure switch not
connected or damaged
• Sensor damaged
• Wiring shorted
• Wiring broken
• Sensor damaged
• Wiring shorted
• Wiring broken
• No circulation of water in
the system
• Air in the system
Blinking (fast)
Cure
• Check the gas flow
to the boiler is regular
• Check the wiring of the electrode
and that it is correctly
positioned and free of any deposits
• Check and change the gas valve
• Adjust the ignition power
• Check the correct
positioning and operation
of the heating sensor
• Check the circulator
• Vent the system
• Check the ionizing electrode
wiring
• Check the card
• Check the wiring
• Check the fan
• Check the pressure switch
• Change the diaphragm
• Fill the system
• Check the sensor
• Check the wiring or change
the sensor
• Check the wiring or change
the sensor
• Check the circulator
• Vent the system
35