Taura 24 MCS
1. OPERATING INSTRUCTIONS
1.1 Introduction
Dear Customer,
Thank you for choosing Taura 24 MCS, a LAMBORGHINI wall-mounting boiler featuring advanced design, cutting-
edge technology, high reliability and quality construction. Please read this manual carefully since it provides important
information on safe installation, use and maintenance.
TAURA 24 MCS is a high-efficiency heat generator for heating and hot water production running on natural or liquefied
petroleum gas, equipped with an open-flue burner with electronic ignition, airtight chamber with forced ventilation
and a microprocessor control system, and designed for installation indoors or outdoors in a partially protected place
(in compliance with EN 297/A6) for temperatures as low as -5°C (-15°C with optional antifreeze kit).
1.2 Control panel
1 System temperature adjustment
2 Hot water temperature adjustment
3 Selector:
0
Off
Summer (hot water only)
Winter (heating + hot water)
RESET Boiler restore
Operation in TEST mode
TEST
4 LEDs indicating functional status and signalling trouble
If the boiler is hooked up with the optional remote timer control, the system and hot water temperature
adjustments can be made solely with the remote control.
Information during operation
During normal operation, the boiler diagnostics control sends information on the state of the boiler via the LEDs
(4 - fig.1):
LED key
On
Off
Red
Green
Yellow
Boiler off
Boiler on stand-by
Heating operation (burner on)
Operation in hot water mode
(burner on)
TEST mode operation
Blinking (fast for trouble)
For other combinations, see chap. 3.4.
Cod. 3540D952 - 11/2008 (Rev. 00)
1
3
Fig. 1
4
2
23