Descargar Imprimir esta página

Briggs & Stratton BRUTE 020300 Manual Del Operario página 20

Publicidad

Idiomas disponibles

Idiomas disponibles

Engine Maintenance
WARNING
Unintentional sparking can result in fire or
electric shock.
WHEN ADJUSTING OR MAKING REPAIRS TO YOUR PRESSURE
WASHER
• Disconnect the spark plug wire from the spark plug and place
the wire where it cannot contact spark plug.
WHEN TESTING FOR ENGINE SPARK
• Use approved spark plug tester.
• DO NOT check for spark with spark plug removed.
Oil
Oil Recommendations
NOTE: Use a high quality detergent oil classified "For Service
SF, SG, SH, SJ" or higher. DO NOT use special additives.
1. Choose a viscosity according to the table below:
NOTE: Synthetic oil meeting ILSAC GF-2, API certification
mark and API service symbol with "SJ/CF ENERGY
CONSERVING" or higher, is an acceptable oil at all
temperatures. Use of synthetic oil does not alter required oil
change intervals.
SAE 30: 40°F and higher (5°C and higher) is good for all
purpose use above 40°F, use below 40°F will cause hard
starting.
10W-30: 0 to 100°F (-18 to 38°C) is better for varying
temperature conditions. This viscosity improves cold
weather starting, but may increase oil consumption above
80°F (27°C).
*Check oil level frequently at higher temperatures.
Synthetic 5W-30: -20 to 120°F (-30 to 40 °C) provides the
best protection at all temperatures as well as improved
starting with less oil consumption.
5W-30: 40°F and below (5°C and below) is recommended
for winter use and works best in cold conditions.
18
Checking Oil Level
Oil level should be checked prior to each use or at least
every 5 hours of operation. Keep oil level maintained.
1. Make sure pressure washer is on a level surface.
2. Remove oil dipstick and wipe dipstick with clean cloth.
Replace and tighten dipstick. Remove and and check oil
level.
3. Verify oil is at "Full" mark on dipstick. Replace and
tighten dipstick.
Adding Engine Oil
1. Make sure pressure washer is on a level surface.
2. Check oil level as described in Checking Oil Level.
3. If needed, slowly pour oil into oil fill opening to the
"Full" mark on dipstick. DO NOT overfill.
NOTICE
Overfilling with oil may cause the engine to not start, or
hard starting.
• DO NOT overfill.
• If over the FULL mark on dipstick, drain oil to reduce oil level to
FULL mark on dipstick.
4. Replace and tighten dipstick.
Changing Engine Oil
Change the engine oil after the first 5 hours and every
50 hours thereafter. If you are using your pressure washer
under extremely dirty or dusty conditions, or in extremely
hot weather, change the oil more often.
CAUTION
Avoid prolonged or repeated skin contact with used motor
oil.
• Used motor oil has been shown to cause skin cancer in certain
laboratory animals.
• Thoroughly wash exposed areas with soap and water.
KEEP OUT OF REACH OF CHILDREN. DON'T
POLLUTE. CONSERVE RESOURCES. RETURN
USED OIL TO COLLECTION CENTERS.
Change oil while engine is still warm from running, as
follows:
1. Drain fuel tank by running pressure washer until fuel
tank is empty.
2. Disconnect spark plug wire and keep it away from
spark plug.
www.brutepower.com

Publicidad