REPLACEMENT ITEMS/SPARE PARTS
The following items can be purchased separately as replacement items or spare parts for your 125 Series Drive DeVilbiss iGo2 POC:
WARNING
Certain oxygen accessories not specified for use with the iGo2 Portable Oxygen Concentrator may impair the performance. ONLY use recommended oxygen delivery
accessories. Do not use a humidifier; this device is not intended for use with, and will not function with, a humidifier. Only manufacturer approved power supplies, cords, and
adapters must be used with this product to ensure proper operation and safety.
Power Supply 120 Watt (AC/DC Adapter) .................................................................................................................................................................................................................... DV68-620
USA Power Cord ........................................................................................................................................................................................................................................................DV51D-606
Continental Europe Power Cord ................................................................................................................................................................................................................................DV51D-607
UK Power Cord ..........................................................................................................................................................................................................................................................DV51D-608
Australia Power Cord .................................................................................................................................................................................................................................................DV51D-609
China Power Cord ......................................................................................................................................................................................................................................................DV51D-614
DC Power Cord (auto adapter) .................................................................................................................................................................................................................................... DV6X-619
Carrying Case ...............................................................................................................................................................................................................................................................125D-670
External Battery Charger
iGo2 Charging Station – US .............................................................................................................................................................................................................................. 125CH-613
iGo2 Charging Station – Continental Europe .................................................................................................................................................................................................... 125CH-614
iGo2 Charging Station – UK .............................................................................................................................................................................................................................. 125CH-615
Spare Battery ...............................................................................................................................................................................................................................................................125D-613
Sieve Bed Package .......................................................................................................................................................................................................................................................125D-619
Cabinet Screws (6) ........................................................................................................................................................................................................................................................125D-621
There are many types of oxygen tubing and cannulas. Certain accessories may impair the device's performance. Use only standard nasal cannula with 25' or less of crush-proof oxygen
tubing with this concentrator. Do not use pediatric (low-flow) nasal cannula or mask. Your homecare provider should also give you advice on the proper usage, maintenance, and
cleaning.
The accessories (nasal cannula, oxygen tubing, etc.) that supply oxygen to the patient must be equipped with a means that, in case of fire, stops the propagation of fire through the
accessory for the safety of the patient and others. A fire activated flow-stop or thermal fuse device, if available, should be used with the oxygen supply accessories. These types of flow-
stop devices stop the flow of oxygen to the patient in the event of fire. This means of fire protection should be located as close to the patient as practicable.
IGO2 POC CARE AND CLEANING
WARNING
To avoid electric shock, do not remove the concentrator cover. The cover
should only be removed by a qualified Drive DeVilbiss technician. Do not
apply liquid directly to the cover or utilize any petroleum-based solvents or
cleaning agents.
Use of harsh chemicals (including alcohol) is not recommended. If
bactericidal cleaning is required, a non-alcohol based product should be used
to avoid inadvertent damage.
Use no lubricants, oils or grease.
Before attempting any cleaning procedures, turn the unit "Off" and disconnect
from AC or DC power.
Do not service or clean this device while in use with a Patient.
EXTERIOR COVER & BATTERY
Clean the concentrator exterior cover and battery as needed:
1. Ensure battery is installed while cleaning the cover.
2. Use a damp cloth or sponge with a mild household cleaner
on the exterior cover and wipe it dry. If battery is removed,
wipe battery bay with a Dry Cloth only.
CAUTION
Do not apply liquid directly to the cover.
3. Wipe battery with a Dry Cloth as needed.
CLEANING
Outer Cabinet
Power Supply and Cords
Carrying Case
Battery
* number of cleaning cycles determined by suggested cleaning interval and expected service life
EN - 14
Suggested cleaning interval
7 days
7 days
7 days
7 days
CARRYING CASE
The carrying case should be cleaned as needed. To clean,
follow these steps:
1. Remove the device from the carrying case before cleaning.
2. As needed, clean the case by using a damp cloth with a
mild household cleaner and wipe dry.
POWER SUPPLY, AC POWER CORD, DC
POWER CORD
1. Disconnect cords from the device and power source before
cleaning.
2. Clean the cords as needed by using a damp cloth with a
mild household cleaner, and wipe dry.
CANNULA AND TUBING
Clean and replace the cannula and tubing according to the
manufacturer's instructions.
NOTE– To minimize the ENVIRONMENTAL IMPACT of the
125 Series Portable Oxygen Concentrator during NORMAL
USE, remove tubing and nasal cannula from the Portable
Oxygen Concentrator, dispose the tubing and nasal cannula
properly. Unplug the 125 Series Portable Oxygen Concentrator
from AC power. Clean the cabinet as listed in the IGO2 POC
CARE AND CLEANING section of this guide.
Number of cleaning cycles *
260
260
260
260
Compatible cleaning method
Mild dish soap (2 tbsp) and warm water (2 cups)
Mild dish soap (2 tbsp) and warm water (2 cups)
Mild dish soap (2 tbsp) and warm water (2 cups)